11258 Corrosion Control for a Waste Water Disposal Line

Monday, March 14, 2011: 1:25 PM
Room 320 D (George R. Brown Convention Center)
Victor Hongbin Wang1 and Keith Allan*2
(1)Clariant Oil Services; (2)Clariant Oil and Ming Services
CORROSION CONTROL FOR A WASTE WATER DISPOSAL LINE

Hongbin Wang and Keith Allan

Clariant Oil Service, North America

2645 N. Crescent Ridge Lane, The Woodlands, Texas 77381

ABSTRACT

This paper contains the results of a case history where corrosion attacks took place in a waste water sour system. Details are also given on the laboratory testing results and development of a corrosion inhibition program for such an environment.

The exposure of the waste water to the air had been taken place from an open pit, which might generate elemental sulfur fine particles in the solution. When solids dropped out from the solution, localized attack was detected in the form of underdeposit corrosion.

<< Previous Abstract | Next Abstract